Instructions–Parts List
MODEL 482
Automatic Metering Valves
Used to provide precise dispense of medium– to high–viscosity sealants and
adhesives in a non–hazardous location.
3200 psi (22.0 MPa, 220 bar) Maximum Fluid Working Pressure
Part No. C02021, Series B
Model 482–B
7/8–18 uns externally threaded fluid inlet boss and 7/16–20 unf mounting hole
1/4 npt(f) material inlet, 1/8 npt(f) material outlet
Part No. C02022, Series C
Model 482–C
7/16–20 unf mounting hole
1/4 npt(f) material inlet, 1/8 npt(f) material outlet
Part No. C02025, Series B
Model 482–E
7/16–20 unf mounting hole
1/4 npt(f) material inlet, 1/4 npt(f) material outlet
Part No. C02078, Series B
Model 482–DA, with double acting air cylinder
7/16–20 unf mounting hole
1/4 npt(f) material inlet, 1/4 npt(f) material outlet
Part No. C02026
Model 482–HA; same as Part No. C02022, with trigger-actuated pistol grip handle
Part No. C02027
Model 482–MS, for moisture sensitive materials;
same as Part No. C02021, with seal fluid reservoir and plugged 7/16–20 mounting hole
U.S. Patent Nos. 3,160,331 and 3,132,775
Important Safety Instructions.
Read all warnings and instructions in this manual.
Save these instructions.
310543E
EN
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Automatic Metering Valves

Instructions–Parts ListMODEL 482Automatic Metering Valves Used to provide precise dispense of medium– to high–viscosity sealants andadhesives in a non

Page 2 - Table of Contents

10 310543Service AMV Disassembly (C02026)This procedure describes how to disassemble thepistol grip metering valve. Refer to Parts informationon page

Page 3 - TOXIC FLUID HAZARD

310543 11ServiceAMV Reassembly (C02026)This procedure describes how to reassemble the pistolgrip metering valve. Refer to Parts information onpage 15

Page 4 - FIRE AND EXPLOSION HAZARD

12 310543ServiceAMV Disassembly (C02027)This procedure describes how to disassemble theautomatic metering valve. Refer to Parts informationon page 16

Page 5 - Installation

310543 13PartsPart Nos. C02021, C02022, and C02025Ref.No. Part No. Description Qty.Ref.No. Part No. Description Qty.1 C02029 BODY; used on C02022, C02

Page 6 - Operation

14 310543PartsPart No. C02078Model 482–DA; with double acting air cylinder and 1/4 npt(f) outletRef.No. Part No. Description Qty.1 C02079 BODY, valve,

Page 7 - Troubleshooting

310543 15PartsPart No. C02026Model 482–HA; Model 482–C with trigger-actuated pistol grip handleRef.No. Part No. Description Qty.Ref.No. Part No. Descr

Page 8

16 310543PartsPart No. C02027This AMV is designed to be used with moisturesensitive materials.Ref.No. Part No. Description Qty.201 C02021 AUTOMATICMET

Page 9 - AMV Reassembly

310543 17AccessoriesUse Only Genuine Graco Parts and AccessoriesFluid NozzlesThese nozzles fit all automatic metering valves covered in this manual.Or

Page 10 - Service

18 310543Technical DataCategory DataMaximum fluid working pressure 3200 psi (22.0 MPa, 220 bar)Minimum fluid working pressure 50 psi (0.34 MPa, 3.4 b

Page 11 - AMV Reassembly (C02026)

310543 19DimensionsC02021, C02022, and C02025 Metering ValvesAir Supply Inlet1/8 npt Minimum80 psi5.50 in. max., 5.19 in. min.(139.7 mm max., 131.8 m

Page 12 - AMV Reassembly (C02027)

2 310543Table of ContentsWarnings 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 5. . . . . . . . . . . . . . . .

Page 13 - C02021–Exploded View

20 310543The Graco Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be

Page 14 - C02078–Exploded View

310543 3SymbolsWarning SymbolWARNINGThis symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions.Caution

Page 15 - Part No. C02026

4 310543WARNINGSKIN INJECTION HAZARDSpray from the metering valve, hose leaks, or ruptured components can inject fluid into your bodyand cause extreme

Page 16 - Part No. C02027

310543 5SetupGround the SystemWARNINGFIRE AND EXPLOSION HAZARDTo reduce the risk of a fire, explosion,and serious injury, proper electricalgrounding o

Page 17 - Accessories

6 310543OperationPressure Relief ProcedureWARNINGINJECTION HAZARDThe system pressure must be manuallyrelieved to prevent the system fromstarting or sp

Page 18 - Technical Data

310543 7TroubleshootingWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow thePressure Relief Pr

Page 19 - Dimensions

8 310543Service AMV DisassemblyThis procedure describes how to disassemble theautomatic metering valve. Refer to Parts informationon pages 13 and 14.

Page 20 - Graco Information

310543 9ServiceAMV ReassemblyThis procedure describes how to reassemble theautomatic metering valve. Refer to Parts informationon pages 13 and 14.NOT