3A1657FENInstructions - Parts HFR Flow Meter KitsFor installation and calibration of flow meters on the HFR dispensing system. For professional use on
Installation 10 3A1657FHFR: Calibration Kit In order to perform the calibration procedure the HFR system must have circulation lines going from the sy
Installation3A1657F 1112. Connect the other end of the hose to the fluid mani-fold as shown in FIG. 18. 13. Connect material return line to the open p
Calibration 12 3A1657FCalibrationThe following procedure describes how to adjust the mass flow rate calculated by the machine. To calculate the mass f
Calibration3A1657F 13Parts and Tools RequiredGX-7DI Only• 5/16 Nut Driver• Adjustable Wrench•Scale• Two large containers with lids (a hole will need t
Calibration 14 3A1657FCalibrate Material Weight Measurement For more detailed instructions regarding steps in this procedure, see Related Manuals list
Calibration3A1657F 15For Probler P2 Gun Only --a. Disconnect both material lines at the gun. See gun manual listed on page 3. b. Attach material lines
Calibration 16 3A1657F11. Press to dispense a shot to prime the material lines.12. Remove container from below the dispense valve.13. Press repeat
Calibration3A1657F 1725. Press to go to the flow meter calibration screen. 26. Enter a value in the Cal. Setpoint input box that is close to what is
Calibration 18 3A1657F38. Prepare dispense valve: For GX7-DI Dispense Valves --a. Close off material flow to the dispense head for BOTH chemicals. Tur
Flow Meter Connector Pinout3A1657F 19Flow Meter Connector PinoutThe system utilizes a 5-pin CAN connection for commu-nication with the flow meter. If
Contents 2 3A1657FContentsContents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Kits . . . . . . . . . . . . . . . . . . . .
Parts 20 3A1657FPartsHFR and NVH: Flow Meter Electronics Kit, 24J318ti17023a101112105106104109110111102107103108Ref Part Description Qty101 24J328 PLA
Parts3A1657F 21HFR: 3000 Series Flow Meter Kits ti17024a203202206204205201Ref Part DescriptionQuantity24J319, S300024J320, G300024J321, G3000HR201 258
Parts 22 3A1657FHFR: 6000 Series Flow Meter Kits ti17016a302303304301305Ref Part DescriptionQuantity24J322, HG600024J323, HG6000HR301 246190 METER, he
Parts3A1657F 23NVH: 24:1 and 16:1 Flow Meter Kits612613611613610609602608607615614601605606Ref Part DescriptionQuantity24T182,24:1 or 16:1 Flow Meter
Parts 24 3A1657FNVH: 1:1 Flow Meter Kits708709707703704706711710701704703705Ref Part DescriptionQuantity24T183,1:1 Flow MeterKit - Cart24T201,1:1 Flow
Parts3A1657F 25HFR: Flow Meter Calibration Kits for Hydraulic Dispense Valves * Parts 407, 408, 409 not shown.ti17025a406404402401403405Ref Part Descr
Parts 26 3A1657FFlow Meter Calibration Kit for Probler P2 Gun, 24J326 Ratio Check Kit for Fusion Gun, 24F227See instruction manual 3A0861 for parts in
Technical Data3A1657F 27Technical DataSee Technical Data in the HFR or HFR for NVH system manuals for more information.Wetted Parts . . . . . . . . .
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
Related Manuals3A1657F 3Related ManualsComponent manuals in English. Manuals are available at www.graco.com. OverviewOn HFR systems, the flow meters a
Installation 4 3A1657FInstallationFlow Meter Electronics Kit 24J3181. Perform Shutdown procedure. See HFR or NVH operation manual for detailed instruc
Installation3A1657F 5HFR: 3000 Series Flow Meter1. Perform HFR Pressure Relief Procedure. See HFR operation manual for detailed instructions. 2. Perfo
Installation 6 3A1657FHFR: 6000 Series Flow Meter1. Perform HFR Pressure Relief Procedure. See HFR operation manual for detailed instructions. 2. Perf
Installation3A1657F 712. Route the flow meter data cable as shown in FIG. 7. 13. Connect the other end to the fluid control module installed in the e
Installation 8 3A1657FNVH Flow Meters1. Perform HFR for NVH Pressure Relief Procedure. See HFR for NVH operation manual for detailed instructions. 2.
Installation3A1657F 98. Connect B (Blue) flow meter and fittings to fluid manifold. See FIG. 12. 9. Connect the supply and return hoses from the appli