3A1657F
EN
Instructions - Parts
HFR Flow Meter
Kits
For installation and calibration of flow meters on the HFR dispensing system. For
professional use only.
HFR: 3000 psi (21 MPa, 207 bar) Maximum Working Pressure
HFR For NVH: 2000 psi (14 MPa, 138 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in the
HFR, Setup-Operation and NVH,
Setup-Operation manuals.
Save all instructions.
ti17008a
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - HFR Flow Meter

3A1657FENInstructions - Parts HFR Flow Meter KitsFor installation and calibration of flow meters on the HFR dispensing system. For professional use on

Page 2 - Contents

Installation 10 3A1657FHFR: Calibration Kit In order to perform the calibration procedure the HFR system must have circulation lines going from the sy

Page 3 - Overview

Installation3A1657F 1112. Connect the other end of the hose to the fluid mani-fold as shown in FIG. 18. 13. Connect material return line to the open p

Page 4

Calibration 12 3A1657FCalibrationThe following procedure describes how to adjust the mass flow rate calculated by the machine. To calculate the mass f

Page 5 - HFR: 3000 Series Flow Meter

Calibration3A1657F 13Parts and Tools RequiredGX-7DI Only• 5/16 Nut Driver• Adjustable Wrench•Scale• Two large containers with lids (a hole will need t

Page 6 - HFR: 6000 Series Flow Meter

Calibration 14 3A1657FCalibrate Material Weight Measurement For more detailed instructions regarding steps in this procedure, see Related Manuals list

Page 7 - 3A1657F 7

Calibration3A1657F 15For Probler P2 Gun Only --a. Disconnect both material lines at the gun. See gun manual listed on page 3. b. Attach material lines

Page 8 - NVH Flow Meters

Calibration 16 3A1657F11. Press to dispense a shot to prime the material lines.12. Remove container from below the dispense valve.13. Press repeat

Page 9 - 3A1657F 9

Calibration3A1657F 1725. Press to go to the flow meter calibration screen. 26. Enter a value in the Cal. Setpoint input box that is close to what is

Page 10 - HFR: Calibration Kit

Calibration 18 3A1657F38. Prepare dispense valve: For GX7-DI Dispense Valves --a. Close off material flow to the dispense head for BOTH chemicals. Tur

Page 11 - 3A1657F 11

Flow Meter Connector Pinout3A1657F 19Flow Meter Connector PinoutThe system utilizes a 5-pin CAN connection for commu-nication with the flow meter. If

Page 12 - Calibration

Contents 2 3A1657FContentsContents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Kits . . . . . . . . . . . . . . . . . . . .

Page 13 - Parts and Tools Required

Parts 20 3A1657FPartsHFR and NVH: Flow Meter Electronics Kit, 24J318ti17023a101112105106104109110111102107103108Ref Part Description Qty101 24J328 PLA

Page 14 - 14 3A1657F

Parts3A1657F 21HFR: 3000 Series Flow Meter Kits ti17024a203202206204205201Ref Part DescriptionQuantity24J319, S300024J320, G300024J321, G3000HR201 258

Page 15 - 3A1657F 15

Parts 22 3A1657FHFR: 6000 Series Flow Meter Kits ti17016a302303304301305Ref Part DescriptionQuantity24J322, HG600024J323, HG6000HR301 246190 METER, he

Page 16 - 16 3A1657F

Parts3A1657F 23NVH: 24:1 and 16:1 Flow Meter Kits612613611613610609602608607615614601605606Ref Part DescriptionQuantity24T182,24:1 or 16:1 Flow Meter

Page 17 - 3A1657F 17

Parts 24 3A1657FNVH: 1:1 Flow Meter Kits708709707703704706711710701704703705Ref Part DescriptionQuantity24T183,1:1 Flow MeterKit - Cart24T201,1:1 Flow

Page 18 - 18 3A1657F

Parts3A1657F 25HFR: Flow Meter Calibration Kits for Hydraulic Dispense Valves * Parts 407, 408, 409 not shown.ti17025a406404402401403405Ref Part Descr

Page 19 - Maintenance

Parts 26 3A1657FFlow Meter Calibration Kit for Probler P2 Gun, 24J326 Ratio Check Kit for Fusion Gun, 24F227See instruction manual 3A0861 for parts in

Page 20 - 20 3A1657F

Technical Data3A1657F 27Technical DataSee Technical Data in the HFR or HFR for NVH system manuals for more information.Wetted Parts . . . . . . . . .

Page 21 - 3A1657F 21

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 22 - 22 3A1657F

Related Manuals3A1657F 3Related ManualsComponent manuals in English. Manuals are available at www.graco.com. OverviewOn HFR systems, the flow meters a

Page 23 - 3A1657F 23

Installation 4 3A1657FInstallationFlow Meter Electronics Kit 24J3181. Perform Shutdown procedure. See HFR or NVH operation manual for detailed instruc

Page 24 - NVH: 1:1 Flow Meter Kits

Installation3A1657F 5HFR: 3000 Series Flow Meter1. Perform HFR Pressure Relief Procedure. See HFR operation manual for detailed instructions. 2. Perfo

Page 25 - 3A1657F 25

Installation 6 3A1657FHFR: 6000 Series Flow Meter1. Perform HFR Pressure Relief Procedure. See HFR operation manual for detailed instructions. 2. Perf

Page 26 - 26 3A1657F

Installation3A1657F 712. Route the flow meter data cable as shown in FIG. 7. 13. Connect the other end to the fluid control module installed in the e

Page 27 - Technical Data

Installation 8 3A1657FNVH Flow Meters1. Perform HFR for NVH Pressure Relief Procedure. See HFR for NVH operation manual for detailed instructions. 2.

Page 28 - Graco Information

Installation3A1657F 98. Connect B (Blue) flow meter and fittings to fluid manifold. See FIG. 12. 9. Connect the supply and return hoses from the appli

Commentaires sur ces manuels