Instructions – Parts List
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441
Copyright 1985, Graco Inc. is registered to I.S. EN ISO 9001
55 GALLON SUPPLY PUMPS
3:1 Presidentr, 4:1 Presidentr,
and 2:1 Monarkr
With drum cover and agitator
Model 220575, Series B
with 3:1 Ratio President Pump
500 psi (3.5 MPa, 35 bar) MAXIMUM FLUID WORKING PRESSURE
Model 230992, Series C
with 4:1 Ratio President Pump
400 psi (2.8 MPa, 28 bar) MAXIMUM FLUID WORKING PRESSURE
Model 230993, Series C
with 2:1 Ratio Monark Pump
200 psi (1.4 MPa, 14.0 bar) MAXIMUM FLUID WORKING PRESSURE
307745G
Read warnings and instructions.
See page 2 for table of contents.
04281A
Model 230992 Shown
Parts
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Instructions – Parts List

Instructions – Parts ListGRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441Copyright 1985, Graco Inc. is registered to I.S. EN ISO 900155 GALLON SUPP

Page 2 - Table of Contents

10 307745Parts DrawingcFig. 31 or 5236(MONARK PUMP SHOWN)109811Model 230993, Series B2:1 Ratio Monark Carbon Steel 55 Gallon Drum SystemIncludes items

Page 3 - MOVING PARTS HAZARD

307745 11Parts ListModel 230992, Series B4:1 Ratio President Carbon Steel 55 Gallon Drum SystemIncludes items 1 to 4, and 6 to 12Model 230993, Series

Page 4 - TOXIC FLUID HAZARD

12 307745Parts Drawing7679AModel 220575, Series B3:1 Ratio President Stainless Steel55 Gallon Drum SystemIncludes items 1–35Ref No. 6 includesitems 6a

Page 5 - System Accessories

307745 13Parts ListModel 220575, Series B3:1 Ratio President Stainless Steel55 Gallon Drum SystemRef PartNo. No. Description Qty1 220564 PUMP, Preside

Page 7 - Operation

307745 15Technical DataCategory Model 220575 Model 230992 Model 230993Ratio 3:1 4:1 2:1Maximum fluid workingpressure500 psi (3.5 MPa, 35 bar) 400 psi

Page 8

16 307745Graco Standard WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workma

Page 9

2 307745Table of ContentsWarnings 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SetupGrounding 5. . . . . . . . . . . .

Page 10 - Parts Drawing

307745 3WARNINGMOVING PARTS HAZARDD The air motor piston can pinch or amputate your fingers.D The rotating blades of the agitator can pinch or amputat

Page 11 - Parts List

4 307745WARNINGFIRE AND EXPLOSION HAZARDImproper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fir

Page 12

307745 5SetupNOTES:D Reference numbers and letters in parentheses inthe text refer to the callouts in the figures and theparts drawing.D Accessories a

Page 13

6 307745SetupThe installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories.Contact your Graco repres

Page 14 - 14 307745

307745 7OperationPressure Relief ProcedureWARNINGPRESSURIZED EQUIPMENT HAZARDThe system pressure must be manually relieved toprevent the system from s

Page 15 - Technical Data

8 307745Operation8. Shut off the air to the pump, open the bleed–typemaster air valve, and open the drain valve (K).Leave the solvent in the system ov

Page 16 - Graco Information

307745 9OperationShutdown and Care of the PumpWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follo