Instructions – Parts ListUHMWPE/NEOPRENE PACKED, FOR PRESSURE WASHINGStainless SteelHydra–Cleanr PumpsFor use in pressure washing applications with wa
10308117OperationShutdown and Care of the PumpWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follo
11308117TroubleshootingWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow thePressure Relief Pr
12308117ServiceDisconnecting the Displacement PumpWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always f
13308117ServiceReconnecting the Displacement Pump1. Lubricate the o-ring (107) and check that it is inplace on the displacement rod (7). Orient thepum
14308117Service224344 Displacement Pump DisassemblyNOTE: For repair and parts information for displace-ment pumps 254999, 15G976, and 224341, seemanu
15308117Service8*19*9*6**23*24*25*26*25*27Detail B: Piston Packings*212132210*16475*1*14(Ref)*29Fig. 540777ADetail A: Throat Packings132Lubricate.Torq
16308117PartsModel 224345, Series A5:1 Ratio Monark Hydra-Clean Pump1081041010196A103102107Ref PartNo. No. Description Qty101 224344 DISPLACEMENT
17308117PartsModel 224347, Series A10:1 Ratio President Hydra-Clean Pump,with riser tube1041010198A108107103102106105112111110109Ref PartNo.
0778A12*8*19*9*6167*1 *1023*24*25*26*29*27*2*11222*135*25*15284141718308117PartsModel 224344, Series ASevere-Duty, Stainless Steel Displacement Pump
19308117PartsModel 224344, Series ASevere-Duty, Stainless Steel Displacement PumpIncludes items 1–29Ref PartNo. No. Description QtyRef PartNo. No. Des
2308117Table of ContentsSymbols 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings 2. . . . . . . . . . . . . . . .
20308117Notes
21308117Technical Data (10:1 President)Category DataMaximum fluid working pressure 1800 psi (125 bar)Maximum air input pressure 180 psi (12.5 bar)Pump
22308117Technical Data (5:1 Monark)Category DataMaximum fluid working pressure 600 psi (42 bar)Maximum air input pressure 120 psi (8.4 bar)Pump cycles
23308117DimensionsPumpModelA B C224346,247146,224347,903295,25499928.38 in.(721 mm)14.63 in.(372 mm)13.75 in.(349 mm)224345 25.25 in.(641 mm)11.5 in.(
24308117Graco Standard WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workman
3308117WARNINGSKIN INJECTION HAZARDSpray from the gun, leaks or ruptured components can inject fluid into your body and cause extremelyserious injury,
4308117WARNINGFIRE AND EXPLOSION HAZARDImproper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fire
5308117InstallationGeneral InformationNOTE: Reference numbers and letters in parenthesesin the text refer to the callouts in the figures and theparts
6308117InstallationSystem AccessoriesWARNINGA bleed-type master air valve (D) and a fluid drainvalve (J) are required in your system. These acces-sori
7308117InstallationFig. 2KEYA PumpB Pump Runaway ValveC Air Line LubricatorD Bleed-Type Master Air Valve (required, for pump)E Pump Air RegulatorF Air
8308117OperationPressure Relief ProcedureWARNINGSKIN INJECTION HAZARDThe system pressure must be manuallyrelieved to prevent the system fromstarting o
9308117OperationStarting and Adjusting the PumpWARNINGMoving parts can pinch or amputate your fingers orother body parts. When air is supplied to the