Instructions – Parts List
UHMWPE/NEOPRENE PACKED, FOR PRESSURE WASHING
Stainless Steel
Hydra–Cleanr Pumps
For use in pressure washing applications with water and cleaning solutions only.
For professional use only.
Part No. 224345, Series A
5:1 Ratio Monarkr Pump
600 psi (42 bar) Maximum Fluid Working Pressure
120 psi (8.4 bar) Maximum Air Input Pressure
Part No. 224346, Series A
10:1 Ratio Presidentr Pump
1800 psi (125 bar) Maximum Fluid Working Pressure
180 psi (12.5 bar) Maximum Air Input Pressure
Part No. 247146, Series A
Part No. 261631, Series A
10:1 Ratio Presidentr Pump
1800 psi (125 bar) Maximum Fluid Working Pressure
180 psi (12.5 bar) Maximum Air Input Pressure
Part No. 224347, Series A
10:1 Ratio Presidentr Pump, with riser tube
1800 psi (125 bar) Maximum Fluid Working Pressure
180 psi (12.5 bar) Maximum Air Input Pressure
Part No. 903295, Series A
10:1 Ratio Presidentr Pump, with riser tube
1800 psi (125 bar) Maximum Fluid Working Pressure
180 psi (12.5 bar) Maximum Air Input Pressure
308117M
ENG
Model 224346 Shown
0195B
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Hydra–Cleanr Pumps

Instructions – Parts ListUHMWPE/NEOPRENE PACKED, FOR PRESSURE WASHINGStainless SteelHydra–Cleanr PumpsFor use in pressure washing applications with wa

Page 2 - Table of Contents

10308117OperationShutdown and Care of the PumpWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follo

Page 3 - MOVING PARTS HAZARD

11308117TroubleshootingWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow thePressure Relief Pr

Page 4 - TOXIC FLUID HAZARD

12308117ServiceDisconnecting the Displacement PumpWARNINGTo reduce the risk of serious injury whenever youare instructed to relieve pressure, always f

Page 5 - Installation

13308117ServiceReconnecting the Displacement Pump1. Lubricate the o-ring (107) and check that it is inplace on the displacement rod (7). Orient thepum

Page 6

14308117Service224344 Displacement Pump DisassemblyNOTE: For repair and parts information for displace-ment pumps 254999, 15G976, and 224341, seemanu

Page 7

15308117Service8*19*9*6**23*24*25*26*25*27Detail B: Piston Packings*212132210*16475*1*14(Ref)*29Fig. 540777ADetail A: Throat Packings132Lubricate.Torq

Page 8

16308117PartsModel 224345, Series A5:1 Ratio Monark Hydra-Clean Pump1081041010196A103102107Ref PartNo. No. Description Qty101 224344 DISPLACEMENT

Page 9

17308117PartsModel 224347, Series A10:1 Ratio President Hydra-Clean Pump,with riser tube1041010198A108107103102106105112111110109Ref PartNo.

Page 10 - Operation

0778A12*8*19*9*6167*1 *1023*24*25*26*29*27*2*11222*135*25*15284141718308117PartsModel 224344, Series ASevere-Duty, Stainless Steel Displacement Pump

Page 11 - Troubleshooting

19308117PartsModel 224344, Series ASevere-Duty, Stainless Steel Displacement PumpIncludes items 1–29Ref PartNo. No. Description QtyRef PartNo. No. Des

Page 12

2308117Table of ContentsSymbols 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warnings 2. . . . . . . . . . . . . . . .

Page 13

20308117Notes

Page 14 - Displacement Pump Reassembly

21308117Technical Data (10:1 President)Category DataMaximum fluid working pressure 1800 psi (125 bar)Maximum air input pressure 180 psi (12.5 bar)Pump

Page 15

22308117Technical Data (5:1 Monark)Category DataMaximum fluid working pressure 600 psi (42 bar)Maximum air input pressure 120 psi (8.4 bar)Pump cycles

Page 16

23308117DimensionsPumpModelA B C224346,247146,224347,903295,25499928.38 in.(721 mm)14.63 in.(372 mm)13.75 in.(349 mm)224345 25.25 in.(641 mm)11.5 in.(

Page 17 - ; 1/2 npt(m) x

24308117Graco Standard WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workman

Page 18 - Includes items 1–29

3308117WARNINGSKIN INJECTION HAZARDSpray from the gun, leaks or ruptured components can inject fluid into your body and cause extremelyserious injury,

Page 19

4308117WARNINGFIRE AND EXPLOSION HAZARDImproper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fire

Page 20

5308117InstallationGeneral InformationNOTE: Reference numbers and letters in parenthesesin the text refer to the callouts in the figures and theparts

Page 21

6308117InstallationSystem AccessoriesWARNINGA bleed-type master air valve (D) and a fluid drainvalve (J) are required in your system. These acces-sori

Page 22 - Technical Data (5:1 Monark)

7308117InstallationFig. 2KEYA PumpB Pump Runaway ValveC Air Line LubricatorD Bleed-Type Master Air Valve (required, for pump)E Pump Air RegulatorF Air

Page 23 - Mounting Hole

8308117OperationPressure Relief ProcedureWARNINGSKIN INJECTION HAZARDThe system pressure must be manuallyrelieved to prevent the system fromstarting o

Page 24 - Graco Information

9308117OperationStarting and Adjusting the PumpWARNINGMoving parts can pinch or amputate your fingers orother body parts. When air is supplied to the