Vue de la page 20
Setup
313876F 21
Setup
NOTE: See Typical Installation diagram.
2.
1. Perform Setup procedure for feed system compo-
nents. See feed system manuals. See Related
Manuals on page 3.
2. Place an in-line air pressure regulator, air-water
separator/filter, and shut-off/bleed valve between
the air supply and the control solenoids.
3. Connect each 1/4 in. outside diameter supplied air
line to the corresponding control solenoid. See
Component Identification starting on page 15.
4. On the Motor Driven PD44, if a non-Graco motor is
used, install the motor onto the metering valve. See
Motor Mounting Diagram, page 23.
5. On the Motor Driven PD44, connect the required
electrical power to the metering valve. See Motor
Specifications, page 43.
6. Connect chemical lines from feed system to meter-
ing valve material inlets. See Component Identifi-
cation starting on page 15.
Typical Installation
FIG. 7
Metering Valve
A Side Pump
A Side Material Tank (optional)
A Side Fluid Shut-Off Valve
Air Supply
Air Shut-off and Bleed Valve
B Side Pump
B Side Fluid Shut-Off Valve
B Side Material Tank
Air Pressure Regulator
User Supplied
Air-Water Separator/Filter
Control Solenoids