Graco 311876F Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Graco 311876F. Graco 311876F User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
311876F
EN
Instructions - Parts List
4-Ball Lower Retrofit
Connection Kits
Connection kits for 4-Ball Lowers. For professional use only.
See the Connection Kit Usage Charts on pages 2-5
to select the correct connection kit for your lower and motor.
A Shield Kit may also be required. See manual 406876
to order the correct shield kit for your pump.
Important Safety Instructions
Read all warnings and instructions in your
pump Operation manual. Save these instruc-
tions.
TI16810a
Connection Kit 24J185
shown mounted on a
President air motor
Contents
Connection Kit Usage Chart for President
®
Air
Motors, E-Flo
®
DC Electric Motors, and
Viscount
®
I+ Hydraulic Motors . . . . . . . . . . . . 2
Connection Kit Usage Chart for Senator
®
, Bulldog
®
,
NXT
®
2200, and NXT
®
3400 Air Motors, E-Flo
®
DC Electric Motors, and Viscount
®
II Hydraulic
Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connection Kit 288202 . . . . . . . . . . . . . . . . . . . . . . 6
Connection Kit 288209 . . . . . . . . . . . . . . . . . . . . . . 9
Connection Kit 288208 . . . . . . . . . . . . . . . . . . . . . 13
Connection Kit 288504 . . . . . . . . . . . . . . . . . . . . . 17
Connection Kit 24F308 . . . . . . . . . . . . . . . . . . . . . 20
Connection Kits 24J185 (shown) and 24J186 . . . 24
Connection Kit 24F065 . . . . . . . . . . . . . . . . . . . . . 27
Connection Kit 24J390 . . . . . . . . . . . . . . . . . . . . . 30
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 32
Vue de la page 0
1 2 3 4 5 6 ... 31 32

Résumé du contenu

Page 1 - Connection Kits

311876FENInstructions - Parts List4-Ball Lower Retrofit Connection KitsConnection kits for 4-Ball Lowers. For professional use only.See the Connection

Page 2 - 2 311876F

Connection Kit 288209 10 311876FPump Performance ChartsNOTE: See pages 7-8 for NXT 2200 and NXT 3400 Per-formance Charts.Fluid Outlet PressureTo find

Page 3 - 311876F 3

Connection Kit 288209311876F 111 HP Motor (1400 lb maximum force) with 1000cc LowerFluid PressureABpsi (MPa, bar)Fluid Flow in gpm (lpm)Ccycles per mi

Page 4

Connection Kit 288209 12 311876F2 HP Motor (2800 lb maximum force) with 1500cc LowerFluid PressureABpsi (MPa, bar)Fluid Flow in gpm (lpm)Ccycles per m

Page 5

Connection Kit 288208311876F 13Connection Kit 288208Connects 4-Ball Lower with Torqueable Throat Packings to Bulldog or Senator Air MotorNOTE: See the

Page 6 - Connection Kit 288202

Connection Kit 288208 14 311876FPump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (MPa/bar/psi) at a specific flow (lpm/gpm) a

Page 7

Connection Kit 288208311876F 15KeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pres

Page 8 - NXT 3400 with 1500cc Lower

Connection Kit 288208 16 311876FKeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pre

Page 9 - Connection Kit 288209

Connection Kit 288504311876F 17Connection Kit 288504Connects 4-Ball Lower with Torqueable Throat Packings to President Air MotorNOTE: See the Connecti

Page 10 - Pump Performance Charts

Connection Kit 288504 18 311876FPump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (MPa/bar/psi) at a specific flow (lpm/gpm) a

Page 11

Connection Kit 288504311876F 19KeyA 1.17 MPa, 11.7 bar (170 psi) air pressureB 0.7 MPa, 7 bar (100 psi) air pressureC 0.5 MPa, 4.9 bar (70 psi) air pr

Page 12

Connection Kit Usage Chart for President® Air Motors, E-Flo® DC Electric Motors, and Viscount® I+ Hydraulic Motors 2 311876FConnection Kit Usage Chart

Page 13 - Connection Kit 288208

Connection Kit 24F308 20 311876FConnection Kit 24F308Connects 4-Ball Lower with Spring Loaded Throat Packings to Bulldog or Senator Air MotorNOTE: See

Page 14

Connection Kit 24F308311876F 21Pump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (MPa/bar/psi) at a specific flow (lpm/gpm) an

Page 15 - Senator with 2000cc Lower

Connection Kit 24F308 22 311876FKeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pre

Page 16 - Bulldog with 2000cc Lower

Connection Kit 24F308311876F 23KeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pres

Page 17 - Connection Kit 288504

Connection Kits 24J185 (shown) and 24J186 24 311876FConnection Kits 24J185 (shown) and 24J186Connects 4-Ball Lower with Spring Loaded Throat Packings

Page 18

Connection Kits 24J185 (shown) and 24J186311876F 25Pump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (MPa/bar/psi) at a specif

Page 19 - President with 2000cc Lower

Connection Kits 24J185 (shown) and 24J186 26 311876FKeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8

Page 20 - Connection Kit 24F308

Connection Kit 24F065311876F 27Connection Kit 24F065Connects 4-Ball Lower with Spring Loaded Throat Packings to Viscount I+ Hydraulic MotorNOTE: See t

Page 21

Connection Kit 24F065 28 311876FPump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (psi/MPa/bar) at a specific fluid flow (lpm/

Page 22

Connection Kit 24F065311876F 29PUMP OUTLET PRESSUREPUMP DELIVERY (Test Fluid: No. 10 Motor Oil)HYDRAULIC OIL CONSUMPTIONpsi (MPa, bar)05(19)20(76)25(9

Page 23

Connection Kit Usage Chart for President® Air Motors, E-Flo® DC Electric Motors, and Viscount® I+ Hydraulic Motors311876F 3253033 1000 288504 (17-19)

Page 24 - Parts List and Drawing

Connection Kit 24J390 30 311876FConnection Kit 24J390Connects 4-Ball Lower with Spring Loaded Throat Packings to Viscount II Hydraulic MotorNOTE: See

Page 25

Connection Kit 24J390311876F 31Pump Performance ChartsFluid Outlet PressureTo find fluid outlet pressure (psi/MPa/bar) at a specific fluid flow (lpm/g

Page 26 - President with 1000cc Lower

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 27 - Connection Kit 24F065

Connection Kit Usage Chart for Senator®, Bulldog®, NXT® 2200, and NXT® 3400 Air Motors, E-Flo® DC Electric Motors, andViscount® II Hydraulic Motors 4

Page 28

Connection Kit Usage Chart for Senator®, Bulldog®, NXT® 2200, and NXT® 3400 Air Motors, E-Flo® DC Electric Motors, andViscount® II Hydraulic Motors311

Page 29 - 311876F 29

Connection Kit 288202 6 311876FConnection Kit 288202 Connects Old Style 4-Ball Lower to NXT 2200 or NXT 3400 Air Motor, or E-Flo DC Electric MotorNOTE

Page 30 - Connection Kit 24J390

Connection Kit 288202311876F 7Pump Performance ChartsNOTE: See pages 10-12 for E-Flo DC Performance Charts.Fluid Outlet PressureTo find fluid outlet p

Page 31

Connection Kit 288202 8 311876FKeyA 0.7 MPa, 7 bar (100 psi) air pressureB 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pres

Page 32 - Graco Information

Connection Kit 288209311876F 9Connection Kit 288209Connects 4-Ball Lower with Torqueable or Spring Loaded Throat Packings to NXT 2200 or NXT 3400 Air

Commentaires sur ces manuels