Instructions–Parts ListIM5™ Inline Electronic MeterFor use with petroleum-based and synthetic oils, antifreeze, andwindshield washer fluid onlyModel 2
10 308687TroubleshootingPRESSURIZED EQUIPMENT HAZARDThe equipment stays pressurized until pressure ismanually relieved. To reduce the risk of serious
11308687AccessoriesShutoff valve 108458Install upstream from the meter. Shuts off fluid supplyfrom the pump. 1/2–14 npt(f) both ends.Thermal Relief
12 308687Graco Standard WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workma
2 308687SymbolsWarning SymbolWARNINGThis symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions.Caution
3308687FIRE AND EXPLOSION HAZARDImproper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition andresult in a fire or ex
4 308687InstallationThese meters must be installed in-line as part of a dispense system as shown in Fig. 1. The typical installationshown is only a g
5308687InstallationGroundingThe use of PTFE tape on threaded connections tothe meter is not recommended, because it couldinterrupt the grounding conti
6 308687OperationSleep ModeThe meter automatically shuts down the display afterone minute of non-use.Activation ModeThere are two ways to activate the
7308687OperationChanging the Measurement Units and Calibration FactorNOTE: A one liter Weights and Measures ap-proved container is required for calib
8 308687ServiceReplacing the BatteryFIRE AND EXPLOSION HAZARDOnly replace the battery in anon-hazardous location, away fromflammable fluids or fumes.Y
9308687Service7262BFig. 514metalcover3Replacing the Electronic ControlFollow this procedure to replace the electronic control:1. Relieve the pressure.