Instructions–Parts List
307707ZAP
ENG
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
HIGH–FLO SERIES
Surge Tanks
These tanks reduce fluid surging in a high– or medium–volume, low–pressure
fluid system. For professional use only.
7139A
Model 220157, Series E
on Surge Tank Stand Kit 218742
Model 238983, Series C
on Surge Tank Stand Kit 218742
Model 233736, Series A
7287B
TI1898B
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Surge Tanks

Instructions–Parts List307707ZAPENGImportant Safety InstructionsRead all warnings and instructions in this manual.Save these instructions.HIGH–FLO SE

Page 2 - List of Models

10 307707OperationModels 238983, 238984, 238985, 238986, 238987, 238988, 218509, and 220157WARNING Always follow the Pressure Relief Procedureon page

Page 3 - PRESSURIZED EQUIPMENT HAZARD

11307707OperationModels 238983, 238984, 238985, 238986, 238987, 238988, 218509, and 220157relief valve captank charge valve captank charge valveModel

Page 4 - MOVING PARTS HAZARD

12 307707OperationModel 233736WARNING Always follow the Pressure Relief Procedureon page 9 before you remove the surge tankfor any reason. Tighten a

Page 5 - Installation

13307707TroubleshootingWARNINGTo reduce the risk of serious injury, includingsplashing fluid in the eyes or on the skin, alwaysfollow the Pressure Rel

Page 6

14 307707Service(Models 218509 and 220157)Installing Diaphragm and Seal Repair KitDiaphragm and Seal Repair Kits are available and canbe ordered separ

Page 7

15307707Service(Models 238983, 238984, 238985, 238986, 238987, 238988)Installing Diaphragm Repair KitDiaphragm and Seal Repair Kit 248079 is available

Page 8

16 307707Service(Model 233736)Diaphragm RepairWARNINGFollow the Pressure Relief Procedure on page 9before you check or service the surge tank orremove

Page 9

17307707PartsModel 218509, Series Ecarbon steel,2 npt(f) inlet/outlet6342631271b1a1b82728291b7143ADetail3838see detailTorque to 63 to 73 N-m (46

Page 10 - Operation

18 307707Parts1bModel 220157, Series Eelectropolished stainless steel,1.25 npt(f) inlet, 1.25 npt(f) outlet2728271b1a1b86312638see detail7143ADe

Page 11

19307707PartsModels238983, 238986 Series Celectropolished stainless steel, 2 npt(f) inlet/outlet238984, 238987 Series Celectropolished stainless steel

Page 12

2 307707Table of ContentsWarnings 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . InstallationAll Models 5. . . . . . . .

Page 13 - Troubleshooting

20 307707PartsModel 233736, Series Astainless steel, 1/4 bspp(f) air port, 3/4 bspp(f) fluid portRef PartNo. No. Description Qty.1 198776 COVER, fluid

Page 14 - (Models 218509 and 220157)

21307707Dimensional DrawingsModel 218509Model 220157648 mm (25.5 in.)383 mm (15.1 in.)2 – 11.5npt(f) fluidport, inlet /outlet2 – 11.5npt(f) fluidpor

Page 15

22 307707Dimensional Drawings300 mm (11.8 in.)Height:102 mm(4.0 in.)3/4 bspp(f) fluid port1/4 bspp(f) air portModel 233736TI1898BStand Mounting H

Page 16 - (Model 233736)

23307707Technical DataCategory DataMaximum fluid working pressure Models 238983, 238984, 238985, 238986, 238987, 238988: 300psi (2.1 MPa, 21 bar)Model

Page 17 - Model 218509, Series E

24 307707Graco Standard WarrantyGraco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workma

Page 18 - Model 220157, Series E

3307707SymbolsWarning SymbolWARNINGThis symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions.Caution S

Page 19 - 238984, 238987 Series C

4 307707WARNINGFIRE AND EXPLOSION HAZARDImproper grounding, poor ventilation, open flames or sparks can cause a hazardous condition andresult in a fir

Page 20 - Model 233736, Series A

5307707InstallationAll ModelsGroundingGround the tank and the rest of your system. See Fireand Explosion Hazard on page 4.Static electricity is genera

Page 21 - Dimensional Drawings

6 307707InstallationModels 238983, 238984, 238985, 238986, 238987, 238988, 218509, and 220157NOTE: Refer to page 8 to install Model 233736.Installing

Page 22 - Stand Mounting Hole Layout

7307707InstallationModels 238983, 238984, 238985, 238986, 238987, 238988, 218509, and 220157Models 218509,238983, 238984,238985, 238986,238987, 238988

Page 23 - Technical Data

8 307707InstallationModel 233736Model 233736 surge tank (A) must be installedhorizontally (see Fig. 4).Install the surge tank on a short riser tube (B

Page 24 - Graco Information

9307707OperationAll ModelsPressure Relief Procedure WARNINGTo reduce the risk of an injury from splashing fluidor moving parts, follow the Pressure Re

Commentaires sur ces manuels