Instructions - Parts
Dura-Flo
Pumps
Stainless Steel Pumps with Severe-Duty Rod and Cylinder. For professional use only.
See pages 3-6 for model information, including maximum working pressure.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
TI8357a
TI8358a
7847
II 2 G
311828H
EN
Vue de la page 0
1 2 3 4 5 6 ... 33 34

Résumé du contenu

Page 1 - Dura-Flo

Instructions - PartsDura-Flo™ PumpsStainless Steel Pumps with Severe-Duty Rod and Cylinder. For professional use only.See pages 3-6 for model informat

Page 2 - Contents

Installation 10 311828HAir Line AccessoriesFor air-powered pumps, install the following accessories in the order shown in FIG. 1, using adapters as ne

Page 3 - P16 M S E

Installation311828H 11Key:APumpB Wall BracketD Air Line LubricatorE Bleed-type Master Air Valve (required)F Pump Air RegulatorH Electrically Conductiv

Page 4

Installation 12 311828HKey:APumpB Wall BracketC Hydraulic Supply LineD Hydraulic Return LineE Drain Line (from pressure reducing valve)F Pressure Gaug

Page 5

Operation311828H 13OperationPressure Relief Procedure1. Engage trigger lock.2. Shutoff the pump:a.For air-powered pumps, close the bleed-type master a

Page 6 - Dura-Flo Pumps with Premier

Operation 14 311828HStartup1. Connect the suction kit (T) to the pump's fluid inlet, and place the tube into the fluid supply. 2. Prepare the pum

Page 7 - Warnings

Maintenance311828H 15MaintenancePreventive Maintenance ScheduleThe operating conditions of your particular system determine how often maintenance is r

Page 8 - 8 311828H

Troubleshooting 16 311828HTroubleshooting1. Relieve the pressure, page 13. 2. Check all possible causes and problems before dis-assembling the pump.*

Page 9

Repair311828H 17RepairRequired Tools• Set of adjustable wrenches• Large pipe wrench• 2-5/8 in. wrench• Torque wrench• Rubber mallet• O-ring pick• Larg

Page 10 - Fluid Line Accessories

Repair 18 311828H5. Screw the nuts (107) onto the tie rods (106). Torque as noted in FIG. 3.6. Screw the coupling nut (103) onto the motor shaft (MS)

Page 11 - 311828H 11

Notes311828H 19Notes

Page 12 - 12 311828H

2 311828HContentsModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Dura-Flo Pumps with NXT™ Air Motors Part No. Matrix

Page 13 - For hydraulic-powered pumps

Parts 20 311828HPartsDura-Flo Pumps with NXT Air MotorsPump Part No.Ref. Nos. and Descriptions101 102 103 104 105 106 107 108MOTOR; see 311238LOWER; s

Page 14 - Shutdown

Parts311828H 21P24LSE N22LNO 261657186925 184129 15H370 15H562 101712 112887P24MSE N22LTO 261657186925 184129 15H370 15H562 101712 112887P25DSE N34DN0

Page 15 - Maintenance

Parts 22 311828HDura-Flo Pumps with Premier Motors7848101102103104105108106107Pump Part No.Ref. Nos. and Descriptions101 102 103 104 105 106 107 108MO

Page 16 - Troubleshooting

Parts311828H 23Dura-Flo Pumps with Viscount Hydraulic MotorsTI8355a101102103104105108106107Pump Part No.Ref. Nos. and Descriptions101 102 103 104 105

Page 17 - Reconnect the Lower

Dimensions 24 311828HDimensionsTI8357aDura-Flo Pumps with NXT Air MotorsTI8358aDura-Flo Pumps with Viscount Hydraulic MotorsABCDABCDDura-Flo Pumps wit

Page 18 - 18 311828H

Mounting Hole Layouts311828H 25Mounting Hole LayoutsNXT Model 2200NXT Model 3400NXT Model 6500TI8069ATI8071ATI8070A6.186 in.(157 mm)Three 5/8-11 Tie R

Page 19 - 311828H 19

Mounting Hole Layouts 26 311828HViscount0653Four 11 mm(0.437 in.)Mounting Holes88 mm (3.464 in.)Three M16 x2.0 Tie RodHoles50.8 mm (2.0 in.)94.3 mm (3

Page 20 - 20 311828H

Technical Data311828H 27Technical DataPump Performance Charts (see pages 28-33)Fluid Outlet PressureTo find fluid outlet pressure (MPa/bar/psi) at a s

Page 21 - 311828H 21

Technical Data 28 311828HKeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi)

Page 22 - 22 311828H

Technical Data311828H 29KeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi) a

Page 23 - 311828H 23

Models311828H 3ModelsDura-Flo Pumps with NXT™ Air Motors Part No. MatrixCheck your pump’s identification plate (ID) for the 6-digit part number of you

Page 24 - Dimensions

Technical Data 30 311828HKeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi)

Page 25 - Mounting Hole Layouts

Technical Data311828H 31KeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi) a

Page 26 - Viscount

Technical Data 32 311828HKeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi)

Page 27 - Technical Data

Technical Data311828H 33KeyA 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressureB 0.5 MPa, 4.9 bar (70 psi) a

Page 28 - 28 311828H

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 29 - 311828H 29

Models 4 311828HDura-Flo Pumps with NXT™ Air Motors Part Nos. (continued)Pump Part No., SeriesLower Part No. Lower Model, PackingsAir Motor Part No. R

Page 30 - 30 311828H

Models311828H 5Dura-Flo Pumps with NXT™ Air Motors Part Nos. (continued)Pump Part No., SeriesLower Part No. Lower Model, PackingsAir Motor Part No. Ra

Page 31 - 311828H 31

Models 6 311828HDura-Flo Pumps with Viscount® Hydraulic MotorsCheck your pump’s identification plate (ID) for the 6-digit part number of your pump. To

Page 32 - 32 311828H

Warnings311828H 7WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Page 33 - (YDRAULIC/IL#ONSUMPTION

Warnings 8 311828HMOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts.• Keep clear of moving parts.• Do not operate eq

Page 34 - Graco Information

Installation311828H 9InstallationGroundingThe equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an esca