Graco 3A1569B Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 38
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Component Identification
14 3A1569B
Main Power Switch
Located on right side of unit, page 11. Turns heater
power ON and OFF . Does not turn
heater zones or pumps on.
Actual Temperature Key/LED
Press to display actual temperature.
Press and hold to display electrical current.
Target Temperature Key/LED
Press to display target temperature.
Press and hold to display heater control circuit
board temperature.
Temperature Scale Keys/LEDs
Press or to change temperature scale.
Heater Zone On/Off Keys/LEDs
Press to turn heater zones on and off. Also clears
heater zone diagnostic codes, see page 35.
NOTE: LEDs flash when heater zones are on. The dura-
tion of each flash shows the extent that the heater is
turned on.
Temperature Arrow Keys
Press , then press or to adjust tem-
perature settings in 1 degree increments.
Temperature Displays
Show actual temperature or target temperature of
heater zones, depending on selected mode. Defaults to
actual at startup. Range is 32-190°F (0-88°C) for A and
B, 32-180°F (0-82°C) for hose.
Circuit Breakers
Located inside Reactor cabinet.
°
F
°
C
Ref. Size Component
CB1 50 A Hose Secondary (single)
CB2 30 A Hose Primary (double)
CB3 25 A Heater A (double)
CB4 25 A Heater B (double)
CB1
CB2
CB3
CB4
ti17569a
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 37 38

Commentaires sur ces manuels